Special Reminder:
The indicated global retail price only for your reference. Contact with us to get more discount and its current inventory quantity of us which located in your country.












Feature
| Battery Parameters | ||||||||
| Item | Spec | |||||||
| Cell | LiFePO4 | |||||||
| Number of modules | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| Batteries configuration | 16S1 | 16S2P | 16S3P | 16S4P | 16S5P | 16S6P | 16S7P | 16S8P |
| Rated capacity | 100A | 200Ah | 300Ah | 400Ah | 500Ah | 600Ah | 700Ah | 800Ah |
| Available capacity | 5.12kWh | 10.24 kWh |
15.36 kWh |
20.48kWh | 25.6k Wh |
30.72kWh | 35.84 kWh |
40.96kWh |
| Weight(Kg) | 55kg | 95kg | 135kg | 175kg | 215kg | 255kg | 295kg | 335kg |
| Dimensions(L×W×H) (mm) |
675× 375× 400 |
675× 375× 560 |
675× 375× 720 |
675× 375× 880 |
675× 375× 1040 |
675× 375× 1200 |
675× 375× 1360 |
675× 375× 1520 |
| Rated voltage | 51.2V | |||||||
| Resistance | IR≤0.6mΩ | |||||||
| Charge voltage | 58.4V | |||||||
| Discharge cut-off voltage | 40V | |||||||
| Standard charging current | 0.25C | |||||||
| Standard discharging current | 0.5C | |||||||
| Max continuous discharge current | 1C | |||||||
| Communication interface | RS485 | |||||||
| Light | ALM / RUN / SOC | |||||||
| Cycle Life | 5000 cycles(0.2C3 charge , 0.2C3 discharge, capacity) | |||||||
| Operating temperature | Charging:0℃~55℃ ;Discharging:-10℃~55℃; | |||||||
| Storage temperature | 1 month: -20℃~45℃ 1 year:0℃~35℃ | |||||||
| Weight(Kg) | 40±0.5Kg | |||||||
| Relative Humidity | 65±20% | |||||||
| Delivery Voltage | ≥48V | |||||||
| Charge retention and capacity recovery capability |
Standard charge the battery, and then put aside at roomtemperature for 28d or 55 ℃ for 7d, Charge retention rate≥90%, Recovery rate of charge≥90% | |||||||
| Inverter parameters | |
| Battery type | Lead-acid or lithium battery |
| Rated battery input voltage | 48Vminimum starting voltage 44V |
| Maximum charging current of hybrid charging | 80A |
| Battery voltage range | 40Vdc~60Vdc ± 0.6Vdc |
| PV input parameters | |
| Maximum PV open circuit voltage | 500Vdc |
| PV operating voltage range | 120-500Vdc |
| MPPT voltage range | 120-450Vdc |
| Maximum PV input current | 22A |
| Maximum PV input power | 5500W |
| Maximum PV charging current | 80A |
| Mains supply input parameters | |
| Maximum charging current of commercial power | 60A |
| Rated input voltage | 220/230Vac |
| Input voltage range | UPS:(170Vac~280Vac)±2% APL:(90Vac~280Vac)±2% |
| Frequency | 50Hz/ 60Hz |
| Commercial charging efficiency | >95% |
| Transition time (bypass and inverter) | 10ms |
| Maximum bypass overload current | 40A |
| AC output parameters | |
| Output voltage waveform | Pure sine wave |
| Rated output voltage (Vac) | 230Vac (200/208/220/240Vac) |
| Rated output power (VA) | 5000(4350/4500/4750/5000) |
| Rated output power (W) | 5000(4350/4500/4750/5000) |
| Peak power | 10000VA |
| On-load motor capacity | 4HP |
| Output frequency range (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz |
| Maximum efficiency | >92% |
| No-load wear | ECO:≤50W Normal:≤25W |
| BMS Parameters & Functions | ||||
| No. | feature | Parameters | Note | |
| 1 | Hibernate function |
Activation state to Resting state |
BMS have manual and automatic dormancy function, after the external voltage is off-line and no discharge, the BMS automatically enters dormancy state after the duration reaches 24 h. BMS can also be put into sleep by software instructions or manually, when the BMS enters the overdischarge protection state, and after the duration is maintained, the BMS enters the sleep state. | Parameters can be set |
| Resting state to Activation state | 1.Charging 2.connect RS485 3.Press RESET key 1S |
|||
| 2 | Hardware switch function |
Activation state to Resting state |
(Press “RESET”key 3-6S) | |
| Resting state to Activation state |
Long press the reset key 1S, charging activates, communication activates |
|||
| 3 | Heating function | Activation condition-10C° | Optional | |
| 4 | Charging current limiting |
5A | Default value | |
| 5 | Over-voltage protection |
Alarm value | 56.8V | Default value |
| Activation value | 58.4V | Default value | ||
| Release value | 51.75V | Default value | ||
| 6 | Cell Over-voltage protection |
Alarm value | 3.55V | Default value |
| Activation value | 3.65V | Default value | ||
| Release value | 3.45V | Default value | ||
| 7 | Cell under-voltage protection | Activation value | 40V | Default value |
| 8 | Cell under-voltage protection |
Alarm value | 2.75V | Default value |
| Activation value | 2.65V | Default value | ||
| Release value | 2.8V | Default value | ||
| 9 | Discharge high temperature protection |
Alarm value | 45℃ | Default value |
| Activation value | 50℃ | Default value | ||
| Release value | 40℃ | Default value | ||
| 10 | Discharge low temperature protection |
Alarm value | -5℃ | Default value |
| Activation value | -10℃ | Default value | ||
| Release value | 0℃ | Default value | ||
| 11 | high-temperature protection |
Alarm value | 45℃ | Default value |
| Activation value | 50℃ | Default value | ||
| Release value | 40℃ | Default value | ||
| 12 | Charge low-temperature protection |
Alarm value | -5℃ | Default value |
| Activation value | -10℃ | Default value | ||
| Release value | 5℃ | Default value | ||
| 13 | Primary over-current protection | Alarm value | 55A | |
| Activation value | 60A | |||
| Delay | 1S | |||
| Release | Automatic release after 1minute | |||
| 14 | Secondary over-current protection | Activation value | 60A | |
| Delay | 500mS | |||
| Release | Automatic release after 15 minutes | |||
| 15 | Short-circuit protection |
current | 280A | Default value |
| Delay | 300us | Default value | ||
| Release | Automatic recovery of charging or disconnecting | |||
| 16 | BMS logging function |
yes | Record warning information, battery voltage, capacity, temperature, etc. |
|
| 17 | BMS history feature |
yes | More than 500 records | |
| 18 | Cell capacity metering function |
SOC & SOH | ≤5% | |
| 19 | Detection precision of BMS |
Current | ≤ 2% | |
| Voltage | ≤ 10mV | |||
| Capacity | ≤ 5% | |||
| Temperature | ≤ 2℃ | |||
| 20 | Balance function | Charge Balance | Activation value:3.5V Activation Voltage difference: 30mV |
|
| 21 | Remote monitoring functions |
yes | ||
| 22 | Remote alarm functions |
yes | ||
| 23 | Remote cut-OFF functions |
yes | ||
| 24 | ESD protection | To meet the requirements of GB/T 17626.2-2006, it can withstand 15KV (air discharge) 8KV(contact discharge) impact, and the components are free from damage and work normally. | ||
Certifications